Machine translation and artificial intelligence are increasingly being used by pharmaceutical companies to prepare multilingual regulatory documentation. But how safe is it to rely on algorithms to translate documents that support the authorisation of medicinal products and provide essential information to healthcare professionals?
A study published on 14 October 2026 in the journal Information (MDPI) shows that conventional machine translation evaluation methods may fail to detect errors that change the clinical meaning of a document, even when the translated text appears grammatically correct.
In their study, Quality-by-Design Framework for Evaluating AI-Driven Machine Translation in Regulatory Affairs, Darya Filatova, Hocine Kadi and Florian Pereme of Product Life Group propose evaluating the translation of Summaries of Product Characteristics (SmPCs) not only in terms of linguistic accuracy but also according to the potential regulatory and clinical consequences of errors.
Why a grammatically correct translation can still be dangerous
Machine translation is commonly evaluated using metrics such as BLEU, chrF, TER and COMET. These tools assess different aspects of translation quality, but aggregate scores do not necessarily reflect the clinical or regulatory significance of individual errors.
For example, an incorrect date in an administrative section and the replacement of the CYP3A4 enzyme identifier with CYP2D6 in a drug interaction section may have a limited effect on an overall translation score. However, their potential consequences are very different.
The second error is potentially much more serious. CYP3A4 and CYP2D6 are different enzymes involved in drug metabolism, and confusing them could lead to an incorrect interpretation of how a medicinal product interacts with other medicines. Depending on the pharmacological context, this could affect the assessment of potential interactions, prescribing decisions and patient safety. Unlike an obvious grammatical mistake, such an error may remain unnoticed because the translated sentence can still read naturally and appear technically plausible.
This illustrates a fundamental limitation of machine translation: linguistic fluency does not guarantee pharmacological accuracy.
The researchers therefore propose taking the functional purpose of individual SmPC sections and their associated risks into account. Particular attention is required for clinical instructions, pharmacovigilance and drug interactions, where even a relatively small change in meaning may have significant consequences.
Importantly, the section that is most difficult to translate is not necessarily the one that presents the greatest risk. For example, toxicology proved particularly challenging for the translation model, while pharmacovigilance and drug interactions were identified as particularly important safety-critical domains.
This means that the intensity of translation review should not be determined solely by linguistic complexity.
What artificial intelligence can check automatically
To improve translation reliability, the researchers developed a multi-layer validation system combining automated rules, terminology resources and large language models (LLMs).
Automated checks can identify discrepancies in numerical values, dosages, units of measurement, enzyme identifiers and other elements that should remain unchanged during translation.
The study also places particular emphasis on MedDRA terminology, which is used in pharmacovigilance.
However, automated verification has clear limitations.
If a translation changes CYP3A4 to CYP2D6, an automated rule can identify the discrepancy by comparing the identifiers.
But if the translation reverses the meaning of a drug interaction — for example, by incorrectly stating which medicinal product affects the other — the terminology may remain unchanged and the sentence may still be grammatically correct.
This illustrates why automated terminology and consistency checks cannot replace a thorough review of the translated content. Identifying the correct enzyme name or medicinal product is only part of the task. The relationship between the substances, the direction of the interaction and the resulting clinical implications must also be preserved.
A qualified human translator with appropriate pharmaceutical knowledge can assess the meaning of the complete sentence in its clinical context, rather than simply checking whether individual terms and numbers match the source document.
This is where specialist review becomes essential. Qualified professionals must assess not only the language but also the medical meaning of the translated information.
Large language models cannot replace expert review
The study also evaluated the use of a locally deployed large language model as an additional translation quality-control tool.
The results showed that such a system can help identify potential problems and prioritise segments for human review. However, the LLM’s agreement with expert assessments of error severity remained limited, with a Cohen’s kappa coefficient of 0.316 (n = 156).
The expert evaluation itself also revealed the challenges involved in assessing translation quality. Agreement between the two expert groups when classifying the severity of errors was κ = 0.376.
The authors therefore consider large language models supporting tools that can help identify potential errors and direct reviewers’ attention towards problematic sections.
However, identifying potential translation errors is not the same as establishing that a document is clinically and regulatorily accurate. Automated systems may overlook subtle changes in meaning, fail to recognise context-dependent errors or incorrectly assess the severity of a translation problem.
Professional human translation and specialist review provide an additional level of control. Experienced translators can assess terminology, sentence structure and meaning in the context of the complete regulatory document. Where necessary, subject-matter experts can verify the underlying pharmaceutical and clinical information.
Final review and approval of translated documents must therefore remain the responsibility of qualified professionals.
Principles for implementing artificial intelligence
The findings suggest several important principles for pharmaceutical companies introducing AI into regulatory affairs workflows.
- Assess meaning, not just language quality: A grammatically correct translation does not guarantee that clinical information has been preserved accurately.
- Apply risk-based review: Particular attention should be given to sections where translation errors could affect patient safety.
- Automate checks of standardised elements: Numbers, dosages, units of measurement, enzyme identifiers and terminology can be monitored using specialised rules.
- Maintain expert oversight: Large language models can assist in identifying errors, but should not independently certify the safety of regulatory documents.
From translation automation to quality assurance
The work by Filatova, Kadi and Pereme contributes to the broader discussion about the use of artificial intelligence in pharmaceutical regulatory affairs.
Its significance lies not simply in demonstrating that AI can accelerate document translation, but in examining how translation quality can be evaluated and controlled according to pharmaceutical quality principles.
For the industry, the central question is no longer just whether machine translation can produce fluent text in different languages. The more important issue is whether the translated document preserves the scientific, clinical and regulatory meaning of the original.
Machine translation can accelerate documentation workflows, while automated verification systems can identify certain categories of errors. However, neither linguistic fluency nor a high automated evaluation score can independently demonstrate that a translated document is safe and accurate.
Although fine-tuning improved translation quality across the evaluated language pairs and metrics, the findings also highlight the limitations of automated quality assessment and the need for further validation. In pharmaceutical regulatory affairs, these limitations reinforce the importance of qualified human translators and specialist review to ensure that scientific, clinical and regulatory meaning is accurately preserved.